Power supply voltage: 5 to 12 VDC.
Output configuration: NPN open collector.
Output code: BCD.
Resolution (divisions): 360.
Connection method: Pre-wired Model.
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection.
Strong shaft E5AN-HTAA2HHBFD User's Manual.
Radial: 120 N, Thrust: 50 N. Proximity Sensor with Separate
E5AN-HTAA2HHBFD
Amplifier Unit for Detection of.
Non-ferrous Metals with Simple.
Sensitivity Adjustment.
Detects aluminum, copper, and other non-ferrous metals.
Product lineup includes compact, flat Sensor Head (E2CY-V3A) and,
model with fluororesin (E2CY-C2AF) for resistance to chemicals.
Simple teaching function to easily adjust sensitivity E5AN-HTAA2HHBFD User's Manual.
Check detection status at a glance with numeric values on a digital display. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sinking).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit E5AN-HTAA2HHBFD User's Manual.
Communications functions: RS-485.
Input type (See note 5.): Platinum resistance thermometer.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5AN-HTAA2HHBFD Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault