OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5AN-HTAA2HH01B-FLK Programmed temperature controller

E5AN-HTAA2HH01B-FLK Programmed temperature controller

OMRON E5AN-HTAA2HH01B-FLK Manual And Instructions
E5AN-HTAA2HH01B-FLK datasheetPDF datasheet
E5AN-HTAA2HH01B-FLK Programmable TypeBasic Type
E5AN-HTAA2HH01B-FLK Programmable TypeUser's Manual
E5AN-HTAA2HH01B-FLK User's Manual
E5AN-HTAA2HH01B-FLK Basic TypeUser's Manual
E5AN-HTAA2HH01B-FLK User's Manual
E5AN-HTAA2HH01B-FLK User's Manual
E5AN-HTAA2HH01B-FLK Communications FunctionsUser's Manual
E5AN-HTAA2HH01B-FLK INSTRUCTION Manual
E5AN-HTAA2HH01B-FLK INSTRUCTION Manual

OMRON E5AN-HTAA2HH01B-FLK Product information and technical parameters:
Brand: OMRON
Name: Programmed temperature controller
Model: E5AN-HTAA2HH01B-FLK
Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.

Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: transfer output (special terminal) E5AN-HTAA2HH01B-FLK.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5AN-HTAA2HH01B-FLK
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors E5AN-HTAA2HH01B-FLK.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5AN-HTAA2HH01B-FLK.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check thhe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5AN-HTAA2HH01B-FLK.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5AN-HTAA2HH01B-FLK.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.


...More relevant models >>>>