OMRON
Home >> Download >> OMRON >> Manual Download >> E5CN-HTQ2H03-FLK Basic Type (Basic Type)

E5CN-HTQ2H03-FLK Basic Type (Basic Type)

Brand: OMRON
Product model: E5CN-HTQ2H03-FLK
Name: E5CN-HTQ2H03-FLK Manual OMRON E5CN-HTQ2H03-FLK Basic Type Basic Type
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - E5CN-HTQ2H03-FLK Basic Type.
Event input points: -.
Transfer output: output (using control output) E5CN-HTQ2H03-FLK
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5CN-HTQ2H03-FLK Basic Type.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultThe main body: terminal type, temperature input type E5CN-HTQ2H03-FLK Basic Type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-HTQ2H03-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CN-HTQ2H03-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Programmed temperature controller
E5CN-HTQ2D
OMRON Programmed temperature controller E5CN-HTQ2D
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTQQ201D-FLK
OMRON Programmed temperature controller E5CN-HTQQ201D-FLK
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTQQ203-FLK
OMRON Programmed temperature controller E5CN-HTQQ203-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTQQ2HHD
OMRON Programmed temperature controller E5CN-HTQQ2HHD
Size: 48 48mm, terminal type. Type: control