Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures E5CN-HTV2BD Basic Type
E5CN-HTV2BD
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type E5CN-HTV2BD Basic Type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications E5CN-HTV2BD Basic Type.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, Single-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using mmodels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5CN-HTV2BD Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5CN-HTV2BD Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.