Size: M12 (Brass); Single; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Connector (M12) E5CN-HV2BD Basic Type.
Sensing distance: 200 mm .
Functions: --.
Model: PNP output
E5CN-HV2BD
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: - E5CN-HV2BD Basic Type.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5CN-HV2BD Basic Type.
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: shield, M12.
Detection range: 2mm.
Output configuration: NPN.
Action mode: NC. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic // manual, RUN/STOP, alarm), interactive display PV/SV E5CN-HV2BD Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HV2BD Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.