Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: 2 point (three phase heater) E5CN-RTUAC100-240 User's Manual.
Communication: RS-485
E5CN-RTUAC100-240
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms E5CN-RTUAC100-240 User's Manual.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately) E5CN-RTUAC100-240 User's Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-RTUAC100-240 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-RTUAC100-240 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.