OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-PPB-A1 AC100-240 PDF datasheet (datasheet)

K3HB-PPB-A1 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-PPB-A1 AC100-240
Name: Time interval table
Sort: PDF datasheet
File language: English
File size: 1.59MB
Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-PPB-A1 AC100-240 PDF datasheet K3HB-PPB-A1 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputs can be applied to a variety of measurement and identificationTime specification: Instantaneous type K3HB-PPB-A1 AC100-240 PDF datasheet.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-PPB-A1 AC100-240 PDF datasheet.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A orr 0 to 5 A) K3HB-PPB-A1 AC100-240 PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can bbe switched between normally open and normally closed K3HB-PPB-A1 AC100-240 PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
Related products
OMRON
Temperature Monitoring Relay
K8AB-TH11S AC100-240
OMRON Temperature Monitoring Relay K8AB-TH11S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm. Supply vol
OMRON
Voltage and current panel meter
K3HB-XAD-A-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-A-DRT1 AC100-240
Input type: DC current input. Output type: D
OMRON
Voltage and current panel meter
K3HB-XAA-1 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-1 AC100-240
Type of input: AC current input. Output type
OMRON
Time interval table
K3HB-PPB-AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-AT11 AC/DC24V
Input type: PNP input type. Event input term