OMRON
Home >> Download >> OMRON >> Manual Download >> E5EC-CC4DSM-013 lnstruction Manual (RS-485 CompoWay/F)

E5EC-CC4DSM-013 lnstruction Manual (RS-485 CompoWay/F)

Brand: OMRON
Product model: E5EC-CC4DSM-013
Name: Programmable Digital Controller
Sort: lnstruction Manual (RS-485 CompoWay/F)
File language: English
File size: 2.32MB
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: -- E5EC-CC4DSM-013 lnstruction Manual.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5EC-CC4DSM-013
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0 E5EC-CC4DSM-013 lnstruction Manual. 2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E5EC-CC4DSM-013 lnstruction Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of thee thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EC-CC4DSM-013 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5EC-CC4DSM-013 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Digital temperature controller
E5EC-CC4ASM-005
OMRON Digital temperature controller E5EC-CC4ASM-005
Size: 48 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5EC-CC2DSM-004
OMRON Digital temperature controller E5EC-CC2DSM-004
Size: 48 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5EC-CC2ASM-014
OMRON Digital temperature controller E5EC-CC2ASM-014
Size: 48 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5EC-CC4DSM-005
OMRON Digital temperature controller E5EC-CC4DSM-005
Size: 48 x 96mm. Control output 1: relay out