The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E5EC-CQ2ASM-012 lnstruction Manual
E5EC-CQ2ASM-012
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EC-CQ2ASM-012 lnstruction Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5EC-CQ2ASM-012 lnstruction Manual. Power supply voltage: 5 to 12 VDC.
Output configuration: Line-driver output.
Resolution (pulses/rotation): 100, 200; 300, 360, 500; 600, 720, 800;
1,000, 1,024, 1,200; 1,500, 1,800, 2,000v; 2,048, 2,500, 3,600.
Connection method: Pre-wired (1 m) (See note.).
Rugged Rotary Encoder.
Incremental model.
External diameter of 50 mm.
Resolution of up to 3,600 ppr.
IP65 (improved oil-proof construction with sealedbearings).
Superior shaft loading performance.
(radial: 80 N, thrust: 50 N)Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makees the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EC-CQ2ASM-012 Manual.
Through the infrared port can be carried out from the frront of the communication E5EC-CQ2ASM-012 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.