Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5EC-CQ2DSM-009 Advanced Type.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
E5EC-CQ2DSM-009 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5EC-CQ2DSM-009 Advanced Type.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E5EC-CQ2DSM-009 Advanced Type.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 1m.
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Size: 96 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remotte SP input, suitable for a wide range of applications E5EC-CQ2DSM-009 Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5EC-CQ2DSM-009 Manual.
A new type of proportional control allows you to control the valve.