Appearance: Unshielded.
Sensing surface: Front.
Sensing distance: 2.5 mm.
Output configuration: PNP.
Model: Operation mode, NO.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5.5 × 5.5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations E5EC-CX2DSM-013 INSTRUCTION MANUAL.
Response frequency: 1 kHz
E5EC-CX2DSM-013
Low current consumption. Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input E5EC-CX2DSM-013 INSTRUCTION MANUAL.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E5EC-CX2DSM-013 INSTRUCTION MANUAL.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15 cm.
Lead wire type: Standard.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors E5EC-CX2DSM-013 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EC-CX2DSM-013 Manual.