OMRON
Home >> Download >> OMRON >> Manual Download >> E5EN-HSS2HH02BF-FLK Basic Type (Basic Type)

E5EN-HSS2HH02BF-FLK Basic Type (Basic Type)

Brand: OMRON
Product model: E5EN-HSS2HH02BF-FLK
Name: OMRON E5EN-HSS2HH02BF-FLK Basic Type E5EN-HSS2HH02BF-FLK Basic Type Manual
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HSS2HH02BF-FLK Basic Type.
Ideal for the thermal input devices of Temperature Controllers E5EN-HSS2HH02BF-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. E3F3-R12 detection methods: Regression reflection type,
Wire lead out type,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyElement type: J (IC) E5EN-HSS2HH02BF-FLK Basic Type.
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-HSS2HH02BF-FLK Basic Type.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the statee of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-HSS2HH02BF-FLK Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5EN-HSS2HH02BF-FLK Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.