OMRON
Home >> Download >> OMRON >> Manual Download >> E5EN-HTAA2HH02BF-FLK Basic Type (Programmable Type)

E5EN-HTAA2HH02BF-FLK Basic Type (Programmable Type)

Brand: OMRON
Product model: E5EN-HTAA2HH02BF-FLK
Name: E5EN-HTAA2HH02BF-FLK Manual OMRON E5EN-HTAA2HH02BF-FLK Programmable Type Basic Type
Sort: Basic Type (Programmable Type)
File language: English
File size: 1.19MB
Power supply voltage: 5 to 24 VDC.
Output configuration: Open-collector output.
Resolution (pulses/rotation): 300, 360, 500, 600, 720, 800, 1,000, 1,024;
1,200, 1,500, 1,800, 2,000, 2,048; 2,500, 3,600.
Hollow-shaft Encoder.
Incremental model.
External diameter of 40 mm.
Resolution of up to 3,600 ppr E5EN-HTAA2HH02BF-FLK Basic Type.
Slim design at only 26 mm thick. Sensing method: Diffuse-reflective E5EN-HTAA2HH02BF-FLK
Appearance: Vertical.
Connection method: Pre-wired Connector (M12).
Sensing distance: 2m.
Water- and Oil-resistant.
Photoelectric Sensor with.
Metal Housing Used for Long.
range Sensing.
Excellent resistance against the water and oil.
Easy application in locations with oil mist.
Long-range sensing up to 30 m with Through-beam models E5EN-HTAA2HH02BF-FLK Basic Type.
Shock resistance rated at 1,000m/s2.
Product lineup includes metal M12 pre-wired connector models.
NPN/PNP selector switch output. E32-DC200E type: standard type; standard,
Specialty: M3 screws (small),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsCase color: Black.
Control output: Voltage output (for driving SSR) E5EN-HTAA2HH02BF-FLK Basic Type.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-HTAA2HH02BF-FLK Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-HTAA2HH02BF-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Programmed temperature controller
E5EN-HTAA2HH01BF-FLK
OMRON Programmed temperature controller E5EN-HTAA2HH01BF-FLK
Size: 48 x 96mm. Category: power AC100 240V
OMRON
Programmed temperature controller
E5EN-HTAA2HH02BD-FLK
OMRON Programmed temperature controller E5EN-HTAA2HH02BD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5EN-HTAA2HH03B-FLK
OMRON Programmed temperature controller E5EN-HTAA2HH03B-FLK
Size: 48 x 96mm. Category: power AC100 240V