GRT1-TS2P REFERENCE MANUAL ()

Brand: OMRON
Product model: GRT1-TS2P
Name: Analog I/O Units
Sort: REFERENCE MANUAL
File language: English
File size: 10.12MB
Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display lamp.
Output rated voltage: DC5 3A ~ 48V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish GRT1-TS2P REFERENCE MANUAL.
You can confirm the action of SSR by using the action display light GRT1-TS2P
Between input and output voltage 4000V. I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/O connections: Terminal block.
Operating mode: Linear counter.
A Counter Unit Supporting Encoder,
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz GRT1-TS2P REFERENCE MANUAL.
Counting can be set to a multiplication factor of 1 or 4.
Wide range of measurement: -8,388,608 to 8,388,607.
One external input and two external outputs are available.
DIN track mounting. Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
OFF-delay time: 15 S.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller GRT1-TS2P REFERENCE MANUAL.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible. Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle contrrol GRT1-TS2P Manual.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control GRT1-TS2P Manual.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
Related products
OMRON
CompoNet Communications Unit
GRT1-ROS2
OMRON CompoNet Communications Unit GRT1-ROS2
Name: Slice I/O Units Digital I/O Units. Sp
OMRON
CompoNet Communications Unit
GRT1-TS2P
OMRON CompoNet Communications Unit GRT1-TS2P
Name: Slice I/O Units Temperature Input. R
OMRON
CompoNet Communications Unit
GRT1-ID4
OMRON CompoNet Communications Unit GRT1-ID4
Name: Slice I/O Units Digital I/O Units. Sp
OMRON
CompoNet Communications Unit
GRT1-CRT
OMRON CompoNet Communications Unit GRT1-CRT
Name: CompoNet Communication Unit. Specifica