Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks GX-MD1621 INSTRUCTION MANUAL.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
GX-MD1621
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track GX-MD1621 INSTRUCTION MANUAL.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 10 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 200 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series GX-MD1621 INSTRUCTION MANUAL.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Ontology: insert terminal type (UL standard certification type).
Pole number: 4 pole.
G2A type plastic sealing type.
Because it is sealed structure, so even in the dust environment, etc..
Can also play a more stable performance than the lock type.
Parts of the relay mechanism are annealed,
Reduce the generation of internal gas.
Compared with the metal sealed relay, the price is cheaperRefer to Safety Precautions for All Power Controllers.
Used in Combination with the G3PA to.
Enable High-precision Temperature Contro.
Use cycle control to achieve power control with little noise.
Used inn combination with the G3PA to connect to single- and,
three-phase loads GX-MD1621 Manual.
Three types of input method available: Internal adjuster,
external adjuster, or DC signals from 4 to 20 mA.
Streamline design. Both DIN track mounting andd screw,
mounting possible GX-MD1621 Manual.
Use linking terminals for close mounting of the G3PA.
Built-in isolation transformer.
Power supply range: 100 to 240 V.