Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7HP-C8 Communications Manual
H7HP-C8
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT) H7HP-C8 Communications Manual.
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Project: Japanese specification model.
Installation method: embedded installation.
All day control operation is simple
Can be carried out on the choice of a few weeks of action. (but only 1 of the week moves and all week specific dates can be set)
ON/OFF time setting has 24 steps H7HP-C8 Communications Manual.
Consistent with CE markers. Through the UL, CSA standard certification.
Rest day function can be easily carried out on holidays, such as the setting of a sudden break.
Test mode function can easily confirm the program.
Can also be used to deal with a sudden change in the way of a semi automatic work.
The pulse action can cope with daylight saving time.
All models are equipped with finger protection function.
Product series contains embedded installation, surface mount, the size of the agreement and other ways.
The same setting can be done with the timer action.
Wiring: Screw terminals.
Mounting method: Flush mounting.
Daily Time Control with Simple Operations,
Specify the operation days.
(However, you can set only one pattern of operation days,
and specified days.)
Up to 12 ON/OFF operations (24 for pulse-output operation).
Special holidays can be handled easily with the holiday,
setting function.
Adjustments for sudden schedule changes can be made eas,
ily using output override and automatic return operation H7HP-C8 Manual.
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe terminals H7HP-C8 Manual.
Conforms to UL, CSA, and CE marking.
Meets a variety of mounting requirements: flush mounting,
surface mounting, and DIN track mounting.