Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input K2CM-Q1M Communications Manual
K2CM-Q1M
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Type of input: AC voltage input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-Q1M Communications Manual.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K2CM-Q1M Communications Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
DepthProduct: 90° Flexible Flat Nozzle Cap.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation K2CM-Q1M Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-Q1M Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.