Brand: OMRON
Product model: K2CM-Q2MA
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 0.29MB
Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON K2CM-Q2MA Communications Manual K2CM-Q2MA
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple K2CM-Q2MA Communications Manual.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input K2CM-Q2MA Communications Manual.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 120-125-130-135-140-145-150V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate workk through high reliability semiconductor circuits K2CM-Q2MA Manual.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time K2CM-Q2MA Manual.
The control power of the relay is not needed, which avoids the trouble of wiring.
Related products
OMRON
Motor Protective Relay
K2CM-2MV
OMRON Motor Protective Relay K2CM-2MV
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q2LV
OMRON Motor Protective Relay K2CM-Q2LV
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q4L
OMRON Motor Protective Relay K2CM-Q4L
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-4MA
OMRON Motor Protective Relay K2CM-4MA
Time specification: Inverse type. Current set