Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K3HB-HTA-CPAC11 User's Manual.
Burnout Detector compatible with a,
wide-range of heater control methods
K3HB-HTA-CPAC11
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-HTA-CPAC11 User's Manual.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic K3HB-HTA-CPAC11 User's Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Static type reverse electric relay K2FW type.
Ensure high accuracy digital UFR/OFR.
Constitute by thee crystal oscillator plus digital IC,
Can achieve high accuracy of frequency detection (adjustment, detection accuracy of less than 0 K3HB-HTA-CPAC11 Manual. 1HZ).
50-60HZ share, can be adjusted arbitrarily in the range of 45-65HZ through the surfacee of the dial switch plate K3HB-HTA-CPAC11 Manual.
Because of the high speed detection, the low frequency relay can detect the system accident before the under voltage relay.