Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wire,
or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load) K3HB-RNB-L1AT11 Communications Manual.
Separate outputs possible for overvoltages and undervoltages K3HB-RNB-L1AT11
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator. Function: Temperature monitoring.
Power supply voltage: 24 VAC/DC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22 K3HB-RNB-L1AT11 Communications Manual. 5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Time specification: Inverse type.
Current setting range: 50 to 160 A K3HB-RNB-L1AT11 Communications Manual.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type of input: AC current input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and currrent signal simulation, measurement and display, identification of the panel table K3HB-RNB-L1AT11 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the opperation trend K3HB-RNB-L1AT11 Manual.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth (panel
Related products
OMRON
Rotating pulse meter
K3HB-RNB-A-DRT1 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-A-DRT1 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RNB-CPAC11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-CPAC11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC100-240
Type of input: AC current input. Output type