Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-VLC-E-DRT1 Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-VLC-E-DRT1
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-E-DRT1 Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA K3HB-VLC-E-DRT1 Communications Manual.
Output type: DeviceNet; -; DeviceNet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard applicable certification (Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noisee K3HB-VLC-E-DRT1 Manual.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 AA at 250 VAC (resistive load) K3HB-VLC-E-DRT1 Manual.
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator.