OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-VLC-FLK1ET11 User's Manual ()

K3HB-VLC-FLK1ET11 User's Manual ()

Brand: OMRON
Product model: K3HB-VLC-FLK1ET11
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-VLC-FLK1ET11 User's Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-VLC-FLK1ET11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Range of pulse interval measurementPower supply voltage: 100 to 240 VAC K3HB-VLC-FLK1ET11 User's Manual.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-VLC-FLK1ET11 User's Manual.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alaarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor K3HB-VLC-FLK1ET11 Manual.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K3HB-VLC-FLK1ET11 Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-BT11 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC100-240
Category: external supply 100mA DC10V. Input