Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 2 relay contact outputs(SPST-NO);
Data transmission output, DC current (0 to 20 mA, 4 to 20 mA).
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) K3HB-VLC-L1ET11 Communications Manual.
Multi-input compatible: DC voltage/current, rotary pulse
K3HB-VLC-L1ET11
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Appearance: surface type S5 shell.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier K3HB-VLC-L1ET11 Communications Manual.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy. Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability K3HB-VLC-L1ET11 Communications Manual.
Equipped with easy to manage and maintain the boot display with LED. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeType: related equipment (sold separately); split type current transformer (CT).
Rated primary side current: 100A.
Rated two secondary current: 1A.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency K3HB-VLC-L1ET11 Manual.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network K3HB-VLC-L1ET11 Manual.
Wide 45mm miniaturization, simple set to the DIN guide.