OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-XAA-L2AT11 Communications Manual ()

K3HB-XAA-L2AT11 Communications Manual ()

Brand: OMRON
Product model: K3HB-XAA-L2AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K3HB-XAA-L2AT11 Communications Manual.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XAA-L2AT11
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) K3HB-XAA-L2AT11 Communications Manual.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-XAA-L2AT11 Communications Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Models: F.
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tribbutaries K3HB-XAA-L2AT11 Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-XAA-L2AT11 Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Voltage and current panel meter
K3HB-XAD-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAD-FLK3AT11 AC/DC24
Input type: DC current input. Output type: c
OMRON
Voltage and current panel meter
K3HB-XAD-ABCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-ABCD1 AC100-240
Input type: DC current input. Output type: B
OMRON
Voltage and current panel meter
K3HB-XAA-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-L2AT11 AC100-240
Type of input: AC current input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-L2AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-L2AT11 AC/DC24
Input type: DC voltage input type. Output ty