Brand: OMRON
Product model: K3HB-XVD-A1
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-XVD-A1 User's Manual.
Manual resetting and automatically resetting supported by one Relay K3HB-XVD-A1
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Category: external supply 100mA DC5V type K3HB-XVD-A1 User's Manual.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XVD-A1 User's Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be appliedMeasuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
SStartup lock and operating time can be set separately K3HB-XVD-A1 Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K3HB-XVD-A1 Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK1BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-FLK1BT11 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Voltage and current panel meter
K3HB-XVA-CPAC11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-CPAC11 AC/DC24
Type of input: AC voltage input. Output type