OMRON
Home >> Download >> OMRON >> Manual Download >> S3200-NSB11-E PROGRAMMING MANUAL ()

S3200-NSB11-E PROGRAMMING MANUAL ()

Brand: OMRON
Product model: S3200-NSB11-E
Name: Safety Light Curtain
Sort: PROGRAMMING MANUAL
File language: English
File size: 11.14MB
Conduit: ½-14NPT.
Applicable cable: Cabtire cable.
Inner diameter (D)of seal rubber: 9 mm.
External diameter of cable: Min, 7.5 mm; Max, 9.5 mm.
Applicable model: D4A-@N.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches S3200-NSB11-E PROGRAMMING MANUAL. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch S3200-NSB11-E Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: Yes S3200-NSB11-E PROGRAMMING MANUAL.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22 S3200-NSB11-E PROGRAMMING MANUAL. 2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control power supply voltage: 48 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availaable in 7 supply voltage configurations S3200-NSB11-E Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S3200-NSB11-E Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products