Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 48 V.
Output current: 0.75 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) S8EX-BP24048LC Connection Guide.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
S8EX-BP24048LC
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) S8EX-BP24048LC Connection Guide.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Power ratings: 240 W.
Input voltage: 2-phase and 3-phase, 380 to 480 VAC, 450 to 600 VDC.
Output Voltage: 24 V.
Output current: 10 A.
Boost Current: 12 A.
Worldwide 3-phase Power Supply.
Resistant in tough environments S8EX-BP24048LC Connection Guide.
Easy and fast installation.
The most compact class on the market.
Wide input range for worldwide applications:
380 to 480 VAC (320 to 576 VAC).
Possible for 2-phase input usage*:
380 to 480 VAC (340 to 576 VAC).
When using the 960 W at 2-phase input, the power rating is 768 W.
DC input can be available*:
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Power Boost function at 120%.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.
Three years Warranty! Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support ffinger touch protection to prevent electric shock S8EX-BP24048LC Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer S8EX-BP24048LC Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"