OMRON
Home >> Download >> OMRON >> Manual Download >> S8VM-05012 Connection Guide ()

S8VM-05012 Connection Guide ()

Brand: OMRON
Product model: S8VM-05012
Name: Digital Controller
Sort: Connection Guide
File language: English
File size: 2.95MB
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110/120 VAC.
Overcurrent detection: Inverse type.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available S8VM-05012 Connection Guide.
Instantaneous type under current sensor available S8VM-05012
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Control power supply voltage: 24 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V S8VM-05012 Connection Guide.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection S8VM-05012 Connection Guide.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Power supply voltage: 100 to 240 VAC.
Output: Relay.
Timer function: No.
Features: Flip-flop function with two inputs/one output.
Offers High-speed Input Response of,
0.1 ms and Equipped with Built-in Timer,
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for,
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and,
the S3D2-DK/EK with one input/output OFF-delay (two circuits),
useful for load control and lamp display,
Power source for the Sensor can be supplied up to 200 mA.
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available. Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Avaailable in 7 supply voltage configurations S8VM-05012 Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8VM-05012 Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Switching Mode Power Supply
S8VM-60012C
OMRON Switching Mode Power Supply S8VM-60012C
Category: incidental cover type. Structure:
OMRON
Switching Mode Power Supply
S8VM-10024CD
OMRON Switching Mode Power Supply S8VM-10024CD
Category: incidental cover type. Structure: D
OMRON
Switching Mode Power Supply
S8VM-05012CD
OMRON Switching Mode Power Supply S8VM-05012CD
Category: incidental cover type. Structure: D
OMRON
Switching Mode Power Supply
S8VM-05024
OMRON Switching Mode Power Supply S8VM-05024
Type: open type. Structure: ottom mounting t