Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 150W.
Output voltage: 48VDC.
Output current: 3.3A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time S8VS-06024 Installation and Operating Manual
S8VS-06024 Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 2.5 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block) S8VS-06024 Installation and Operating Manual.
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22 S8VS-06024 Installation and Operating Manual. 2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Input voltage: 400 ~ 500 VAC3 phase.
Rated power: 240W.
Output voltage: 24V.
Output current: 10A.
DIN guide rail installation, with 5 A ~ 40 A output current of the power supply.
3 phase 400 ~ 500 VAC.
5, 10, 20 and 40 A; 24 VDC output.
High stability, low ripple and low noise level.
Compact design.
Add fuse protection.
Natural draft。
In addition to the CE tag, but also in compliance with UL60950 (CSA22.2-60950), UL508.
Conform to EN61000-3-2.
Parallel / series operation. Appearance: insert type.
Control supply voltage: DC24V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock timme, instantaneous action, etc S8VS-06024 Manual. , are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT orr the relay part is not needed, and the use is simple S8VS-06024 Manual.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple.