Control voltage: 200/220/240 VAC.
Reset: Automatic.
Model: Instantaneous type (See note 1.).
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function SRT2-OD16T SETUP MANUAL.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s
SRT2-OD16T
Protects the motor from reversing without starting it.
before using the K2CM. I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection) SRT2-OD16T SETUP MANUAL.
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported. Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (general purpose) SRT2-OD16T SETUP MANUAL.
Inner diameter (D)of seal rubber: 7 mm.
External diameter of cable: Min, 5.5 mm; Max, 7.5 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards SRT2-OD16T Manual.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) SRT2-OD16T Manual.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)