Optical system: Through-beam.
Measuring width: 10 mm.
Sensing distance: 0 to 500 mm.
Resolution: 4 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Appearance: Separate type.
Optical system: Through-beam.
Measuring width: 28mm ZX-LD40 Introduction Manual.
Sensing distance: 0 to 500mm.
Resolution: 10µm.
Output type: PNP
ZX-LD40
Measurable at any position.
The usual limitations, such as the ''measurement,
area being confined to the center''
or ''large errors due to positioning'',
that used to plague laser measuring sensors,
have now been overcome. Measurements can be,
consistently taken within a 500 mm area,
whatever stage the work is at or whichever way it is inserted ZX-LD40 Introduction Manual.
It can now be set to positions without interference from,
the work feed and without limitations of size of work area. Connection method: Pre-wired connector.
Cable length: 0.5 m.
Sensing distance: 600 ± 400 mm.
Model: PNP output.
A CMOS Laser Sensor That’s.
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments ZX-LD40 Introduction Manual.
Stable measurements for any type of workpiece.
Models available with four different distance specifications.
Long-distance model for up to 1,000 mm.Shape: Screw-shaped.
Dimensions: M10 x 22 mm.
Sensing distance: 2 mm.
Resolution: 1 μm.
High-accuracy Detection of Metal Workpiece Displacement.
Sensor Heads support a wide variety of applications.
Linearity can be adjusted for non-ferrous metals,
such as SUS and aluminum, using the material selection function.
Simple linearity compensation (teaching).
Easily perform calculation for two Sensors by using a Calculating Unit.
Prevent mutual interference for up to five Units by using a Calculating Unit. Item: Station.
Easy temperature and humidity control with an SD Card. Actuator: Sealed (Booted); Sealed roller plunger; AC.
Mounting: Base mounting.
Approved standards: UL CSA.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC moddels have also been added,
to the series ZX-LD40 Manual.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with gground terminals have CE marking ZX-LD40 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)