ZEN Kit: Set containing CPU Unit (ZEN-10C1DR-D-V2),
Connecting Cable, ZEN Support Software, and manual.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
Easy programming is available using the LCD and operation,
buttons ZX-LT010 OPERATION MANUAL. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions
ZX-LT010
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max ZX-LT010 OPERATION MANUAL. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC. Optical system: diffuse type.
Detection distance: 350 positive and negative 135mm.
Beam shape: point beam.
Beam diameter: diameter of 240 M.
Resolution: 20 m.
Cable length: 2m. Optical system: Diffuse reflective.
Beam shape: Line beam.
Sensing distance: 40±10 mm ZX-LT010 OPERATION MANUAL.
Resolution: 2 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Sensor that can be connected: Thermo-Humidity Sensor Head (ZN-THS1__-S).
Display: LCD 7-segment 5-digit 2-step display,
auxiliary information indicator display.
Measurement interval: 10 s, 20 s, 30 s, 1 min, 2 min,
5 min, 10 min, 20 min, 30 min, 1 h.
Calculation function: Instantaneous value, maximum value,
minimum value, average value.
Operating mode: Normal mode, sleep mode.
Recording mode: Continue, ring.
Alarm signal output: Output to photocoupler (External power supply: 12 to 24 VDC,
Load current: Max. 45 mA) Alarm hold setting is possible.
Internal storage device: Internal memory: Approx. 8,500 data items.
External storage device: SD card (to save measured values and to save/read set, values),Recommended SD card: HMC-SD291 (manufactured by OMRON).
Power supply voltage: DC input: 24 VDC±10%, Battery: 2 AAA batteries.
Battery life: Approx. 1 year∗6 (sleep mode, measurement interval off 10 minutes, with 2 AAA nickel metal hydride batteries, with SD card not inserted) ZX-LT010 Manual.
Operating temperature range: 0 to 60°C.
Operating humidity range: 20 to 85% (no condensation).
Weight (packaged): Approx. 500 g.
Accessories: IInstruction Sheet, Startup Guide CD-ROM∗7,
Alarm output connector∗8, DC cable (straight type) ZX-LT010 Manual.
Easy temperature and humidity control with an SD Card.