3G2A5-OD211 OMRON 3G2A5-OD211


Specification: three phase 400V.
Power: 300KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 405kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G2A5-OD211.
The high functionnal specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV 3G2A5-OD211.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function 3G2A5-OD211. Specifications: Standard type.
Impact resistance: 200W.
Resistance to impact resistance: 180.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed OMRON 3G2A5-OD211.
Function name: 3 phase 400V.
Power: 7.5KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched) OMRON 3G2A5-OD211.
Weight: 3.5KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication OMRON 3G2A5-OD211.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 100.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power suppply of the frequency converter is formed 3G2A5-OD211. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 12A.
Weight: 0.9KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.