I/O Terminal Cover For 38-pin block, special type 3G2A5-COV11Provided with a 2-m cable for ladder programming.
Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Grroup-2 High density I/O Unit, No
CS1W-BI102.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No CS1W-BI102.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Model: C200H-DA004 CS1W-BI102.
Input points: 8.Specifications: 8 Kwords without clock.Product name: N@@S1- type CPU Units with 30 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 18; Outputs, 12;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words OMRON CS1W-BI102.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality OMRON CS1W-BI102.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Inputs: 8.Terminal Resistance Unit Mount to an I/O Expansion Unit CV500-TER01Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units OMRON CS1W-BI102.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CS1W-BI102.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.