For 10-slot Backplane.
Model : C500-LK201-V1.
RS-232C/RS-422.Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0 C500-LK201-V1.02 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
C500-LK201-V1.
Model : C500-MR831.C200H Discrete I/O Data Access Console C200H-DAC01Unit type: CS1 CPU Bus Unit.
Product name:FL-net Unit.
Specifications: Communications interface,
100BASE-TX; Communications functions,
With FL-net Ver C500-LK201-V1. 2.0 specifications,
(OPCN-2) Data links and message service;
Max. Units mountable per CPU Unit,4.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.38A; 26V, --.
Standards: UC1, CE.
Connect to Multivendor Controller Networks OMRON C500-LK201-V1.
This Unit allows you to connect to FL-net,
an open network based on Ethernet.
Multivendor FL-net networks can be built to,
combine CS series PLCs with CNC machines,
robots, and PLCs from other manufacturers. Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit OMRON C500-LK201-V1.
Specifications: 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No OMRON C500-LK201-V1.
Words required: 2 words.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.I/O capacity/Mountable Units(Expansion Racks): 2, 560 points/40 Units (3 Expansion Racks max.).
Program capacity: 120K steps.
CJ1H-CPU66H Data memory capacity: 256K words(DM: 32K words, EM: 32K words × 7 bank).
LD instructioName: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
>
Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-LK201-V1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.