Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.05 s to 300 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J
S82Y-H05S FOR S82H-50W
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking. Number of notches: 3 notches.
Output: DPDT.
Reset method: Manual.
Key release position: Center.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28.5 mm below panel.
Wide range of switching capacity from standard to microload.
Oil-resistant IP65 models. E32-TC200BR type: standard type; soft (new standard),
Specialty: M4 screw with casing,
Shape / detection distance (mm): 700; 530; 350 (140),
Standard test object
(minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
S82Y-H05S FOR S82H-50W Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=S82Y-H05S FOR S82H-50W&select=5