Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display
S8E1-01512D
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Type: General-purpose.
G2 models.
Compact, Space-saving Plug-in Type Ideal,
for Pump Panels or Building into Equipment.
Large switching capacity: 5 A at 220 VAC (resistive load).
Easy to handle with DIN rail mounting.
Replace for maintenance without rewiring the socket. Operating: Appearance, 40-dia. head Medium Push-lock Turn-reset With EMS, Indication; Contact Configuration, 3NC (1NC + 1NC + 1NC) .
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts).
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated.
S8E1-01512D Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=S8E1-01512D&select=5