Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 11 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2250 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 44.1 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 38 dB
S8VS-06024
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Function name: 3 phase 400V.
Power: 0.75KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Type: screw terminal type, micro load with cable.
Rated current; 0.1A AC125V.
Driving rod: ball type.
Terminal: screw terminal with cable (right hand side).
Action indicator: no operation indicator.
Compared with D4E performance is stronger, in compliance with the requirements of high durability, high sealing.
Horizontal spring, with improved swing lever ratio of the built-in switch to provide a smooth action effect and a longer period of use.
Protection cover protects built-in switch from dust and oil pollution damage.
The plunger type combined with the solid sealing cover has longer service life.
One touch off connector wiring operation miscellaneous,
And reduce the downtime due to wiring and maintenance.
Gold Plated minimum load type is an ideal choice for electronic control.
Can provide terminal type plastic screw terminal system and terminal type plastic with operation indicator.
Certified by EN, UL, CSA and CCC (China Standard) standard.
Install the pitch and with the characteristics of D4E- - N and D4E.