Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
SGE-225-0-3050N 05000C-05000C
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Classification: Micro load.
Contact gap: H (0.25 mm).
Actuator: Panel mount plunger; Medium OP.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Absolute diameter 65.
High resolution absolute type for detecting instrument and precision positioning.
To achieve a resolution of 12 bits (maximum 4096) of high resolution.
Response frequency is the high speed response of 40kHz
Output with gray code and BCD code.
The shape is smaller than the old one.
Power supply voltage: DC5 ~ 24V.
Output form: BCD.
Output code: open collector output. Actuator: Roller plunger (Metal roller).
Cable length: 3 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 4NC (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
SGE-225-0-3050N 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-3050N 05000C-05000C&select=5