Count input: No-voltage.
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Light-gray body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Sensing method: Through-beam Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: Timer Self Diagnosis Turbo External Diagnosis
SGE-225-2-1830 05000C
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 350W.
Output voltage: 24VDC.
Output current: 14.6A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Number of beams: 100.
Protective height: 2000mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
SGE-225-2-1830 05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-2-1830 05000C&select=5