Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
SGE-245-0-0600 01000C-01000C
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. NO. OF I/O SLOTS: 11 SLOTSCable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 1 m.
AC.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Size: 6 dia.
Type: Low measurement type.
Sensing distance: 4 mm.
Resolution (See note.): 0.1 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Protective tubing length: W1/4 screw.
Lead wire length: 1m.
Element type: K (CA).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
SGE-245-0-0600 01000C-01000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-245-0-0600 01000C-01000C&select=5