Appearance: Shielded, M30.
Sensing distance: 10 mm.
Output: PNP.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms
SGE-245-0-0840 05000C-05000C
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 26.
Protective height: 395mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 120-125-130-135-140-145-150V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.