Lead wire length: 2 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
SGE-245-0-2580 05000C-05000C Actuator: Roller lever (metal lever, bearing roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Size: M18, Shielded.
Sensing distance: 8.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 39 (53).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
SGE-245-0-2580 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-245-0-2580 05000C-05000C&select=5