Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock
SGE-245-3-0300 00150M-00750F
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head. Type: Welding / wire type, M3 screw mounting.
Drive rod: rod type Shibai leaf.
Terminal specification: welding.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
SGE-245-3-0300 00150M-00750F Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=SGE-245-3-0300 00150M-00750F&select=5