Size: 96 x 96mm.
Control output 1: voltage.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility
V-102-1E5
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Actuator: Sealed (Booted); One-way action sealed roller arm lever; DC.
Mounting: Diagonal side mounting.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
V-102-1E5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=V-102-1E5&select=5