Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 18 points.
Outputs points: 12 points.Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with
V-104-1C24
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Power: AC.
Purpose: general purpose type.
Amplifier unitUltra low load action type check switch.
The action force of 0.03N can be used to detect the setting of the card and the paper''s pass.
Quick fit type of single touch installation, corresponding to the thickness of the plate t=0.8, 1, 1.2mm
Realization of single contact wiring with a press connector.
About 45 of the length of the trip to expand the installation of equipment around the degree of freedom of design. Contact type: Microload (125 VAC, 0.1 A; 30 VDC 0.1 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT.
Lighting: Incandescent lamp, 28 VAC/VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. E3JM-R4S4T detection method: Regression reflection type with M.S.R. function,
Connection: terminal plate,
Detection range: 4m.
Output status: ON into the light; light shading ON; switch conversion type.
Output: DC no contact. Function: timer,
2 types of cost reductionActuator: Plunger.
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
V-104-1C24 Operation manual / Instructions / Catalog download link: