Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 100 mm (wide view).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2
WLCA2-THG5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: there.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
WLCA2-THG Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=WLCA2-THG&select=5