Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 1.2A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red).
Main functions: Ion balance adjustment (Automatic and manual)
XS4M-D421-1
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0.1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 1 kg (Approx. 1.8 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, Stand, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues. Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).
XS4M-D421-1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS4M-D421-1&select=5