Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade
G2R-1-SD DC5
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Appearance: Square/Projection type LED lighting,
(without Voltage Reduction Unit) A22L-C.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection distance: infrared 1mmmm.
Output mode: PNP output. Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
G2R-1-SD DC5 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-1-SD DC5&select=5