Type: 1A contact type.
Shape: square.
Terminal shape: terminal for printed board.
Action: instantaneous.
Display mode: do not display.
Operation Department color: black.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-D
G3PE-515B-2H DC12-24
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Field of view: Wide View (Long-distance).
Number of pixels: 760,000 pixels.
Color: PNP.
Field of view/Installation distance: Refer to figure 7 on p.20.
Inspection capabilities, camera options,
and communication options -- this powerful,
heavy weight has it all.
This Vision Sensor provides all of the best-selling,
features found in high-end models without the,
need as in vision system for a separate controller.
This new Smart Camera was designed to attract,
potential customers to try the FQ2 Series. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
G3PE-515B-2H DC12-24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G3PE-515B-2H DC12-24&select=5